previous by dateindexnext by date
previous in topictopic listnext in topic

Subject: RE: [chromapolaris] Slider front panel not working properly

From: "Paul D. DeRocco" <pderocco@...>
Date: 2013-01-02

> From: sukhoy27@...
>
> I just complete to replace the membrane switch Panel , thanks
> to Paul very detailed Photo instructions , and so my Polaris
> model 301420 still play like new !!!
> But probably because is has bend not working for 5/6 years
> something happens and the panel slider from Master Volume to
> the assignable control when moved works only 40% . The
> sliders that has yo be in the centre working position works
> only when moved down , but not moved up.

So what's wrong with the bend? Did you do the lever calibration? That's
LOWER FUNCTION, A, 7, then move both levers through their entire ranges,
then press LOWER FUNCTION again. It's probably a good idea to do all the
calibration procedures, if you can manage to follow them in English.

Sometimes it's possible to take a slider apart, clean it, and put it back
together successfully, but not always. It's easier just to replace it. John
Leimseider had some available back in September. If he doesn't respond to
your query on the mailing list, you could contact him directly at
john.leimseider@.... But try doing all the calibrations first.

--

Ciao, Paul D. DeRocco
Paul mailto:pderocco@...