Hi
The last days I worked a lot with the A100 and tried also to customize
some modules. From this background and from the lot of new ideas of the
discussions here in the last week, I'd like to suggest two technical things:
1.) If possible, please always provide two parallel sockets for each
output. I never have enough multiples. And very often I only want to
split a connection or simply have a measuring point for a voltmeter or
oscilloscope.
2.) the connection traces for sockets on the pcb most times are routed
that way, that any kind of additional normalling ist not possible (or at
least requires breaking up the lines, and rewiring them). Until now most
connections come from the electronics, go to the normalled switch
contact of the socket and are wired through to the in/output contact of
the socket.
It would be much better for any customizing if the connection to the
electronics are connected only to the in/output contact and the
normalled swicth contact would be free for additions.
thanks
Florian