I don't expect any problems with your applications.
As long as the voltages applied to any socket are within -12V...+12V we
guarantee that nothing can be damaged within the A-100. But even voltages
beyond these limits will not damage most of the inputs (e.g. audio inputs
and CV inputs with attenuators). But there is one exception: inputs and
outputs of modules that use voltage controlled switches (e.g. A-150, A-151,
A-152, A-154, A-155, A-148), older versions of A-150 and A-151
(max. -8V...+8V), and CV or audio inputs without attenuators. For these
in/outputs the voltages applied should be within -12V...+12V.
Best wishes
Dieter Doepfer
> -----Ursprüngliche Nachricht-----
> Von:
Doepfer_a100@yahoogroups.com
> [mailto:
Doepfer_a100@yahoogroups.com
]Im Auftrag von redsawcloud
> Gesendet: Freitag, 7. Juli 2006 00:23
> An:
Doepfer_a100@yahoogroups.com
> Betreff: 1 external inputs w/ a-100
>
>
> Would it be dangerous to take an external 1/4" synth output directly into
a VCA and adjust
> the volume to Doepfer signal level Or to use a 4096 sqaure oscillator
running on a 9v
> battery as a trigger source for an adsr What are the risks in bringing in
external signals
> both for audio and triggering without using the A-119
> I'm not sure I understand any details. Thanks for any knowledge.