--- In
Doepfer_a100@yahoogroups.com
, "michaeltritter" <mtritter@...> wrote:
>
> Wondering if Dieter or anyone can help with this one:
>
> I've had 3 G6 racks for a couple of months. None of them have been problematic until
> yesterday, when one of them blew a fuse. I replaced the fuse, and everything worked
> again, until today, when the fuse blew again. I removed most of the modules, and the
fuse
Hi Michael,
I had a problem with a G6 that turned out to be only visable after I removed all the
modules and looked closely at the power supply.
My unit had the old power supply and a part had melted. I was blowing fuses non stop and
couldn't figure out why. If you want to know which part the archives might mention it.
-could have been the transformer. Once I installed the PS2 or whatever the bigger/later
version everything was fine.
TD, NYC as well!