Dieter,
thank you for your response. I was indeed looking to have the 155 move to step 1 on
initiation and I currently manually set it to 8 to achieve this. I was just curious about a
labour saving mod. I quess I'll have to save my pennies to buy an A 154.
Danke,
Stuadh
--- In
Doepfer_a100@yahoogroups.com
, <hardware@...> wrote:
>
> Stuadh
>
> No. A hardware counter (CD4024) is used in the A-155 (no microcontroller)
> for address generation. The positive transition at the reset input of this
> circuit causes to set all addresses to zero.
>
> > Hi,
> >
> > is it possible to mod an A-155 to reset to step 8 rather than 1
>
> No. A hardware counter (CD4024) is used in the A-155 (no microcontroller)
> for address generation. The positive transition at the reset input of this
> circuit causes to set all addresses to zero.
>
> But I can't see a reason to reset to step 8. If you simply "re-define" the
> steps in your sequence (1->8, 2->1, 3->2 ...) you are able obtain the same
> result. Or did I overlook anything
>
> Best wishes
> Dieter Doepfer
>
> P.S. The A-155 in combination with A-154 has a different behaviour. A reset
> signal does not set to step one but only prepares the unit to jump to step
> one with the next clock pulse. Maybe this is the behaviour you want to have.
>
>
>
> > Yours Aye
> >
> > Stuadh
> >
> >
> >
> >
> >
> >
> > Yahoo! Groups Links
> >
> >
> >
> >
> >
> >
>