OK I have had time to check this out and found the following:
 With the A-154 in Forward mode, pressing reset causes the sequence to
 start from step 1 on the next clock cycle if the sequence is running
 or on the next press of the start button if it is stopped.
 With the A-154 in Reverse mode, pressing reset causes the sequence to
 start from step 8 on the next clock cycle if the sequence is running
 or on the next press of the start button if it is stopped.
 I believe this is the correct and desired behaviour for both modes.
 With the A-154 in Pendulum mode, pressing reset causes the sequence to
 start from step 2 on the next clock cycle if the sequence is running
 or on the next press of the start button if it is stopped.
 I would have expected the sequence to restart on step 1 as with the
 forward mode.
 Sorry if I confused anyone with my previous post but I knew I saw this
 behaviour just the other day but I must have been running in pendulum
 mode.
 Regards,
 Adam-V
 --- In
Doepfer_a100@yahoogroups.com
, "Adam-V" <adam-v@...> wrote:
 >
 > It should be the latest version, I only received it from Doepfer on
 > Friday.
 >
 > I'll have to double check the behaviour when I get home from work
 > tonight but I'm certain was mine starting at step 2 when reset was
 > pressed while the sequence was running. It does stay on the current
 > step when you press stop but I can't recall what happens if you then
 > press reset, I'll have to check this tonight too.
 >
 > Cheers,
 > Adam-V