OK I have had time to check this out and found the following:
With the A-154 in Forward mode, pressing reset causes the sequence to
start from step 1 on the next clock cycle if the sequence is running
or on the next press of the start button if it is stopped.
With the A-154 in Reverse mode, pressing reset causes the sequence to
start from step 8 on the next clock cycle if the sequence is running
or on the next press of the start button if it is stopped.
I believe this is the correct and desired behaviour for both modes.
With the A-154 in Pendulum mode, pressing reset causes the sequence to
start from step 2 on the next clock cycle if the sequence is running
or on the next press of the start button if it is stopped.
I would have expected the sequence to restart on step 1 as with the
forward mode.
Sorry if I confused anyone with my previous post but I knew I saw this
behaviour just the other day but I must have been running in pendulum
mode.
Regards,
Adam-V
--- In
Doepfer_a100@yahoogroups.com
, "Adam-V" <adam-v@...> wrote:
>
> It should be the latest version, I only received it from Doepfer on
> Friday.
>
> I'll have to double check the behaviour when I get home from work
> tonight but I'm certain was mine starting at step 2 when reset was
> pressed while the sequence was running. It does stay on the current
> step when you press stop but I can't recall what happens if you then
> press reset, I'll have to check this tonight too.
>
> Cheers,
> Adam-V