Hi Tim,
Thanks for taking the time to respond. Your suggestion worked! I'm very relieved...I'm
sure you can imagine how annoying it has been to have to re-scale every time i turn it on.
thanks again!
sam
--- In
Doepfer_a100@yahoogroups.com
, "Tim Stinchcombe" <timothy@...> wrote:
>
> Hi Sam,
>
> Check that all the socketted ICs are well seated, especially the
> small 8-pin DIL at the top edge of the board, marked '24C16' - that
> is an EEPROM chip and very likely is where such information is stored
> when the power is off. (The square chip below it, 44 pins, is the
> processor, and left of that, another DIL, with 28 pins, is the ROM
> chip holding the software. The only other socketted chip on mine is a
> MAX531, a digital-to-analog converter, so it is unlikely to be that
> causing the problem.)
>
> If that doesn't fix it, then you're going to need some proper help I
> suspect!
>
> Tim
>
>
> --- In
Doepfer_a100@yahoogroups.com
, "sam" <sams2cats@> wrote:
> >
> > hello
> > i'm finding that every time i turn on my modular i have to reset
> the scale on my a190
> > interface. i have saved it using the procedure outlined in the
> manual but still everytime i
> > need to reset it. there was a time when it would periodically
> retain the settings after
> > powering down but now it never seems to. any idea what the problem
> could be it's starting
> > to drive me nuts and i am a patient man.
> > thanks!
> > sam
> >
>