--- In
Doepfer_a100@yahoogroups.com
, "stuadh" <stuadh@...> wrote:
>
> Hi,
>
> my quantizers are out of tune with each other and with my MIDI-CV
> Converter. The converter tracks exactly 1V/Oct but I can't get the
> Quantizers to read 0V when playing the lowest note. You have told me
> already how to adjust the scale on this forum, but after further
> investigation, I now need to adjust the offset, too. I have tried
> adjusting each of the other three trims in turn, but to no avail. The
> first quantizer reads -7.4 mV on the lowest key.
>
In addition, I've just realised that the note cross-overs on both
modules are wrong. For example, when set to Maj Chord, with no
transpose, the 156 doesn't switch to G (on an ascending scale) until
you play A.
How do you set up the Quantizer
> Yours Aye
>
> Stuadh
>