> I have two 5V Low-Cost Adapters (A-100AD5). I have previously used them
> with A-113 and A-190 installed in separate A-100G6 cabinets.
>
> Now I am going to put A-113 and A-190 into same cabinet. Looking at the
> power consumption figures it appears, that two A-100AD5 are still
> needed. Just to make to make sure, I would like to ask, how should the
> A-100AD5:s be installed, when
> - A-113 and A-190 are in the same row/power rail.
Sorry, that's not possible as only one A-100AD5 is allowed for each bus
board.
> - A-113 and A-190 are in different rows.
That's the right solution. Simple connect one A-100AD5 on each bus board.
Best wishes
Dieter Doepfer