Hi Group, Dieter,
I just tested the new modules I got this week and I'm sorry to say that
twice I got some unexpected behaviour. The 3rd button of the Manual Gate
does not seem to generate a signal. Button 1 and 2 are ok, no sign of
any physical damage, the sticker on the back says 'vortest', perhaps
that's a clue
Also the Precision Adder is default connected to the bus board (it
immediately influenced the pitch of the a-111's that are in the same
case) but this is not the behaviour I want, because there's also an
a-190 in the same case, so I will need to adjust a jumper setting, but I
think there's not yet any exact information about this on the website.
This last problem seems more serious because of the warning for possible
short circuit in the a-185-2 text. I have not tried to do any further
testing as I have an a-190 in the same case. Especially new users could
maybe get into trouble if this happens to them and they are not aware
Or am I getting paranoid now
I do like the new jack sockets by the way
Anyway, greetings and happy 2008
Anton