> > Do you mean, that the *knob* settings of A-149-1 affect A-149-2
> >
> > Jari Jokinen
>
> In any case the clock of the A-149-1 QRV section affects the A-149-2. I'm
> not sure if the QRV knob setting and CV affects the A-149-2 too. This
> depends if the A-149-2 are "pre" or "post" the gating function of
> the shift
> register outputs. I'll have to ask Christian who wrote the firmware of the
> A-149-1 if the gate outputs are affected of if the "raw" shift register
> states are taken. A detailed description how the A-149-1 works
> can be found
> on our website (A-149-1 info page).
>
> Best wishes
> Dieter Doepfer
I've got the answer from Christian. The CV of the A-149-1 QRV section does
not affect the A-149-2 outputs as the "raw" shift register data are taken
for the A-149-2. Only the clock of the A-149-1 QRV section triggers the
advance to the next state of the shift register.
Best wishes
Dieter Doepfer