--- In
Doepfer_a100@yahoogroups.com
, neil jendon <n2eil@...> wrote:
>
> for question #2: A-166 has two inverters. Invert-quantize-then
invert again. Would that work
>
not with the a166. the a166 inverters are digital, they just flip
from zero to +10 volts and vise versa, they are no real anlog
inverters for variable voltages. you have to use the a175.
maybe it is a good idea to split the voltage from the binary
zone into the positive and negative parts, the a172 max/min
is perfect for that task. then the negative part can be inverted,
quantized and inverted again with the a175 dual inverter.
best wishes
ingo