> Huge thanks for the very thorough, helpful replies. My idiocy was in
> assuming that the clock out was a simple gate/trigger that I could
> use as an alternative LFO square wave to trigger S&H or something.
Of course you can treat the clock output as a rectangle LFO that is in snyc
with the midi clock. As the midi clock is 96 beats per measure you have to
adjust the clock dividing factor to a suitable value (or use an external
divider). If you e.g. use 6 you obtain a "rectangle LFO" with 1/16 period,
if you choose 12 the period is 1/8. You may e.g. trigger a S&H with this
clock to obtain a stepped voltage that changes e.g. every eighth or
sixteenth. Very useful to control e.g. a VCF with high resonance.
Best wishes
Dieter Doepfer