thanks dieter.
is there a simple relationship between the value of r4 and cv2's
sensitivity i don't want to end up with a 0.3v/octave cv2 :)
best, stu
--- In
Doepfer_a100@yahoogroups.com
, <yahoo@...> wrote:
>
> > hi group,
> >
> > can anyone suggest a way to increase the range of the cv2 input of the
> > a188-2 multitap bbd it won't quite reach an octave/volt. this means i
> > have to use cv1, which is slightly over an octave/volt, and i'm having
> > to use up 8hp of valuable rackspace to attenuate it slightly.
> >
> > great module, though (thanks for the encouraging words, bakis).
> >
> > thanks in advance,
> >
> > stu
>
> To increase the sensitivity of CV2 the value of R4 has to be reduced. R4
> (47k) is located between the CV2 control and the clock socket. If
you want
> to change the scale the 25-turn trimming potentiometer P19 has to be
> adjusted.
>
> Best wishes
> Dieter Doepfer
>