the cv1 jack is normalled to the cv bus,
maybe there is something wrong with the
jack itself or with its bus connection
best wishes
ingo
--- In
Doepfer_a100@yahoogroups.com
, "skp_pete" <skp_pete@...> wrote:
>
> I've had my A-100 synth (started with basic system mini) since new only 5 months ago....
>
> Yesterday after switch on, one of my A-110 osc sounded like it had random voltages going on inside
> It sounded really sick in the guts
>
> no patch leads apart from the osc output so was definately something not right....
>
> my other A-110 was and is fine.
>
> after fraking out for a coupla minutes, i plugged a lead into CV1, and everything's fine. Take the lead out and everything is fine.
>
> The same thing happened again today about 1-2 hours after start up.
>
> the osc goes all sick sounding ..... i plug an unconnected lead into CV1 breifly and everything is fine for the rest of the day (another 8 hours)
>
> what gives
>
> any help or experience
>
> thanks
>