Dear Dieter,
Both of the A-132-3 modules I have (purchased new very recently) pass continuous low level audio signal even when the Gain control is set to zero, the module is switched to Linear, and no external CV signal is applied (although the signal level varies with each VCA). Is there an internal adjustment I could make to fix this
With thanks for your help.
Matt
>In the linear mode the VCA should let pass no signal if the Gain >control is set to zero and no external CV signal is applied (or the >CV attenuator is set to zero). In the exponential mode the situation >is different. Please refer to my message/answer from January 10th 2011 >concerning the lin/exp mode of the A-132-3.
>
> Best wishes
> Dieter Doepfer
>