> > Betreff: 1 A-117 calibration
>
> >
> >
> > Is there any information on calibration for the A-117, I was given one
> > yesterday but it has been detuned off spec, so i would like to
> > return it to
> > factory settings.
> >
> > regards
> >
> > Paul
>
> The two variable oscillators have to be adjusted to about 540 Hz and 800 Hz
> by means of the two trimming potentiometers. The oscillator signals are
> availabel on pin 4 and 6 of the CD40106.
>
> Best wishes
> Dieter Doepfer
>
>
>