Cool, thanks for the response. And thanks for making such amazing products, I'm really loving these otherwise!
--- In
Doepfer_a100@yahoogroups.com
, <yahoo@...> wrote:
>
> > hello, newb here, I apologize in advance if this is a stupid question
> >
> > I've owned a dark energy for a while and recently purchased a
> > dark time. I seem to be having a problem with the sequencer.
> >
> > Out of the box when all steps are set to on/cont. (on the 16 step
> > sequence) the 12th step goes back to 1 and begins again. In other
> > words, its as if the 12th step is set to on/jump. The only way to
> > get the sequencer to go through the sequence 1-16 is to set the
> > 16th and a step before the 12th step to jump, then it runs through.
> >
> > Is this normal I didn't think so and had a replacement sent out
> > and that unit is doing the same thing, so now I'm wondering if
> > I'm missing something.
> >
> > Any help would be appreciated!
>
> Maybe the switch #12 is defective and has to be replaced. I ask you to
> address technical questions that refer to Dark Time to our specialist
> Christian Assall (software (at) doepfer (dot) de). He is the author of the
> Dark Time firmware and knows all details about the unit. Maybe a firmware
> update will solve the problem.
>
> Best wishes
> Dieter Doepfer
>