I have another case, and I have the same 250MA fuse in that one, which has performed perfectly.
I got my modular around 10 years ago...so I don't know if it's the older the new. Is there any code on the casing that would tell me
If it is the old style, would an 800mA fuse hurt Also, if it is a 250MA fuse, is it REQUIRED to be slow-blow
--- In
Doepfer_a100@yahoogroups.com
, <yahoo@...> wrote:
>
> Are you sure that your case contains the old power supply The old power
> supply is out of procuction since about 10 years. If the new supply
> (A-100PSU2) is built into the case an 800 mA fuse is required.
>
> Best wishes
> Dieter Doepfer
>
>
>
> > -----Ursprüngliche Nachricht-----
> > Von:
Doepfer_a100@yahoogroups.com
> > [mailto:
Doepfer_a100@yahoogroups.com
]Im Auftrag von David
> > Gesendet: Freitag, 1. Juni 2012 13:55
> > An:
Doepfer_a100@yahoogroups.com
> > Betreff: 1 Re: My Doepfer is sick :-(
> >
> >
> > I have an idea to install another type of module in its place
> > (once I get more fuses), to see if it boots up. If it does, the
> > modules are the problem. If not, then there's a problem with the
> > power rail. I assure you that the total amperage is below 650Ma.
> > And the fuses are 250 MA, 250V slo-blo 5x20mm.
> >
> > --- In
Doepfer_a100@yahoogroups.com
, <yahoo@> wrote:
> > >
> > > That's really very strange and I have no simple explanation for this
> > > behaviour.
> > >
> > > Please double check if you use the correct fuse (maybe with the
> > last modules
> > > the total current goes beyond the fuse value). Especially pay
> > attention that
> > > a time lag fuse (slow blow) with the correct value has to be used.
> > >
> > > If the fuse value and type are correct: remove some of the
> > other modules and
> > > install one the A-140 to see if indeed the A-140 causes the
> > problem. As you
> > > already mentioned it woul be very odd if both A-140 are faulty (but who
> > > knows ....)
> > >
> > > Best wishes
> > > Dieter Doepfer
> > >
> > >
> > > > -----Ursprüngliche Nachricht-----
> > > > Von:
Doepfer_a100@yahoogroups.com
> > > > [mailto:
Doepfer_a100@yahoogroups.com
]Im Auftrag von David
> > > > Gesendet: Freitag, 1. Juni 2012 07:24
> > > > An:
Doepfer_a100@yahoogroups.com
> > > > Betreff: 1 Re: My Doepfer is sick :-(
> > > >
> > > >
> > > > OK...I tested every module on its own, and they all tested OK
> > > > (didn't blow the fuse), and I began to mount them one at a time
> > > > back into the case. Everything booted properly, until the very
> > > > last one, the A-140, which when I booted after plugging this in,
> > > > caused another fuse to blow. So the A-140 is the culprit.
> > > >
> > > > This is odd, because I have a second A-140, which does the same
> > > > thing. Could it be the position in the chain or along the power rail
> > > >
> > > > --- In
Doepfer_a100@yahoogroups.com
, Florian Anwander
> > > > <fanwander@> wrote:
> > > > >
> > > > > Hello,
> > > > >
> > > > > Dieter wrote the essential things of course. I recommend
> > additionally:
> > > > >
> > > > > * switch the system off
> > > > > * unmount the A-130 and A-140 (also unplug the cables for those two
> > > > > modules at the busboard !!! Dieter forgot to mention that).
> > > > > * replace the fuse and switch the system on again.
> > > > >
> > > > > If the fuse still blows, assumingly something worse happened and I
> > > > > recommend not to act on further, but send it to big city
> > music and ask
> > > > > them to fix it.
> > > > >
> > > > >
> > > > > If the fuse does not blow again
> > > > > * switch off the system
> > > > > * unmount the next module from the frame, but DO NOT unplug
> > its cable.
> > > > > * inspect in detail how the cable is plugged in on this
> > module and how
> > > > > its cable is connected on the busboard. Obey the orientation of the
> > > > > cable on the module and on the busboard. There is a coloured
> > > > wire at one
> > > > > side of the cable.
> > > > > * now connect the A130 the same way. First attach the cable to the
> > > > > module, then connect it to the busboard. Obey the
> > orientiation of the
> > > > > coloured wire (the connector may be "look" to a different side.
> > > > The only
> > > > > important thing is the orientation of the coloured wire !!!)
> > > > > * mount those both module back to the frame (A140 is still
> > unmounted!)
> > > > > * switch on the system
> > > > > * The A130 should work now with turned up gain.
> > > > > * switch off the system
> > > > > * now connect the A140 the same way. Again obey the
> > orientation of the
> > > > > coloured wire!
> > > > > * mount the A140 into the frame
> > > > > * switch on the system
> > > > > * test it.
> > > > > If the fuse blows now again, then the A140 is assumingly
> > broken (or you
> > > > > misplaced a connector again).
> > > > >
> > > > >
> > > > > Florian
> > > > >
> > > > > --
> > > > >
http://fa.utfs.org/
> > > > >
> > > >
> > > >
> > > >
> > > >
> > > > ------------------------------------
> > > >
> > > > Yahoo! Groups Links
> > > >
> > > >
> > > >
> > >
> >
> >
> >
> >
> > ------------------------------------
> >
> > Yahoo! Groups Links
> >
> >
> >
>