Actually, it was 650mA for the cases with the old powers supply. Do you
have a PSU 2 or 1 in the case The PSU 2 is a round transformer core and
PSU 1 is a small black plastic transformer. PSU 2 is 1200mA the PSU 1 is
650mA.
On Wed, Jan 23, 2013 at 12:43 PM, isoldeandisobelle <
isoldeisobelle@...
> wrote:
> **
>
>
> Thank you very much, that is reassuring, I was working on the assumption
> that the maximum total was 650ma.
>
> Best wishes
>
>
> --- In
Doepfer_a100@yahoogroups.com
, achtung_999 wrote:
> >
> > Way within the limits. The Doepfer 6U cases are rated 1,2A I believe.
> >
> > Ernst
> >
> >
> > On Wed, Jan 23, 2013 at 12:09 PM, isoldeandisobelle <
> > isoldeisobelle@...> wrote:
> >
> > > **
>
> > >
> > >
> > > Hi,
> > >
> > > In my 6U case, the current usage of all modules installed amounts to
> the
> > > 650ma limit, this includes the A-113 Sub Harmonic generator, which is
> rated
> > > at 30ma, I have not included the 5v low cost adapter in this total -
> > > although it it installed.....am I still within safe limits
> > >
> > > Kind regards
> > >
> > >
> > >
> >
> >
> > [Non-text portions of this message have been removed]
> >
>
>
>
[Non-text portions of this message have been removed]