Not the clock signal but the reset signal triggers the reset, i.e. a
positive voltage (not the rising slope !) at the reset input resets all
A-160 outputs to zero and A-161 to step 1. The reset is static, i.e. as long
as the reset signal is high all A-160 outputs remain low and A-161 stays at
step 1 (even if clock pulses are present). Clock and reset are independent
from each other for A-160/A-161 combo (in contrast to the A-154 where a
reset signal triggers kind of a "wait state" and the actual reset is carried
out at the next clock pulse that follows the reset).
Best wishes
Dieter Doepfer
> -----Ursprungliche Nachricht-----
> Von:
Doepfer_a100@yahoogroups.com
> [mailto:
Doepfer_a100@yahoogroups.com
]Im Auftrag von Peter Sedin
> Gesendet: Freitag, 3. Mai 2013 08:09
> An: doepfer_a100
> Betreff: 1 a-160/161 question
>
>
> At muff wiggler I read that the clock pulses does not reset the divisions
after reset.
> like in the picture.. why not
>
>
> Mvh
>
> Peter H.K Sedin