Hello Dave
Am 03.01.2014 13:18, schrieb
dave_doobie@...
:
> Hi, I recently had both my A-190.1 and A-113 Sub harmonic generator
> working on the same rail of my LC6 case. Each module had an AD5 +%v
> adapter on the same rail and both worked fine for a while then they both
> decided to stop working.
>
> Now, the A-190.1 has all the LEDs illuminated and the A-113 shows no
> indication of working. I have placed them on different rails now with
> their adapters. I have tried resetting the A-190.1 but get no further
> than the LEDs lighting up. All my other modules are working correctly.
>
> Has anybody else had a similar experience
>
> Could it be that the AD5s are broken
Assumingly they are broken.
It is not allowed to have two adaptors in the same row. It is a bit like
http://us.123rf.com/400wm/400/400/rony029/rony0291011/rony029101100011/8253264-ritter-turnier-vektor.jpg
On one rail you need only one adaptor for all modules which require 5Volts.
Florian