Please refer to page 2 of the A-143-1 user's manual. Fig. 3 shows the
trigger behaviour in detail.
The A-143-1 can be retriggered only in the decay phase. A new trigger that
appears in the attack phase has no effect as the module is already in the
attack state. A retrigger would require that the envelope capacitor is
discharged at each rising edge of gate signal. This does not apply for the
A-143-1. The attack phase is completed after each rising edge of the gate
signal.
Best wishes
Dieter Doepfer
> Does the trigger on the 143-1 envelope behave like a re-trigger
> In other words, does it re-trigger when it receives a signal, no
> matter in which phase it is
> Thanks,
>
>
> Martin