> To: Doepfer_a100@yahoogroups.com
> From: Doepfer_a100@yahoogroups.com
> Date: Wed, 26 Nov 2014 10:52:23 +0100
> Subject: AW: AW: 1 A-156, heat sensitive
>
> > Hi Dieter,
> >
> > I will test this as soon as I have some spare time. I rearranged the case a bit to see if it will solve the heat problem.
> > The problem only happens for the top quantizer, the lower one works perfectly even if the top one stops working.
> >
> > Best regards,
> >
> > Janne
>
> If the lower quantizer works perfectly I don't think that it's a major problem. I suspect that the switching contact of the upper
> trig in socket causes the problem. Internal a fast trigger signal is generated which is routed to the trigger inputs of the module
> via the switching contact of the trig in sockets -provided that no external trigger signal is applied. If the switching contact does
> not work perfectly (e.g. because of corrosion, dust or material fatigue) the trigger signal is missing and the conversion stops.
>
> Best wishes
> Dieter Doepfer
>
>
>
> ------------------------------------
>
> ------------------------------------
>
>
> ------------------------------------
>
> Yahoo Groups Links
>