You find my answers written inline
Best wishes
Dieter Doepfer
> -----Ursprüngliche Nachricht-----
> Von:
Doepfer_a100@yahoogroups.com
[mailto:
Doepfer_a100@yahoogroups.com
]
> Gesendet: Donnerstag, 20. August 2015 03:04
> An:
Doepfer_a100@yahoogroups.com
> Betreff: 1 Timing Capacitor Mod
>
>
> Hi to you all,
>
> Who knows, if the attack will become shorter too, when decreasing C2 of A-140 ADSR.
yes, all time parameters (A,D,R) will be reduced by the same percentage.
> I have a 47nF capacitor to do that; would that be okay for that
This would divide all times by about 2
> "A-140: Timing capacitor (short range): C2
> Standard value: 100nF = 0.1uF (foil/mylar)
> Polarity: none"
>
> I also wondering what the practical effect is, when decreasing C6 of A-119.
> I mean, what/where is going to smooth
decreasing > less smooth (higher frequency of the simple low pass)
increasing > more smooth (lower frequency of the simple low pass)
> "A-119: Timing (smoothing) capacitors for envelope follower: C6
> Standard value: 100 nF = 0,1uF (foil/mylar)
> Polarity: none "