I hadn't thought to check the 156 for adjustment. I've been struggling with tuning for some time now and almost always have a 156 in the patch. Thanks for bringing this to my attention. I'll check the scale of my 155 while I'm at it!
On Thursday, August 18, 2016, Jacco Ville jaccoville@... 1 < Doepfer_a100@yahoogroups.com > wrote:
....And I certainly will do that.Learning learning....
Funny thing, I am more collecting and adjusting my Doepfer setup (or Dieter room as my wife is calling it) then making sounds.But I think it is the best way to know the working of every part of this system.
Cheers
Jacco Ville
Verstuurd vanaf mijn iPhone SE Lunatik
Op 18 aug. 2016 om 12:19 heeft yahoo@... 1 < Doepfer_a100@yahoogroups.com > het volgende geschreven:
> .... By the way ;-)
>
> I found out the attenuator function of P1 and P2
> Very handy to set the threshold of the quantizer behaviour.
> I noticed that with critical voltages from my A155's with a knob
> fully cw the voltage of 0.970V in 1V modus was not enough to get
> a full scale from C to C.
> Now I made the threshold of the A156 a few mV earlier to deal with
> this problem.
>
> Cheers
>
> Jacco Ville
> The Netherlands
That's a solution. But the correct way would be to adjust the A-155 so that
it outputs 1.0V in 1V mode. For this a trimming potentiometer (P9') is
available on the upper A-155 potentiometer board.
Best wishes
Dieter Doepfer