The trimming pot on the A-198 pcb can be used to adjust the pressure CV
 offset. But I'm not sure if the range is sufficient to compensate the offset
 in case of a 15V supply. You have to try out.
 Best wishes
 Dieter Doepfer
 > -----Ursprüngliche Nachricht-----
 > Von:
Doepfer_a100@yahoogroups.com
 [mailto:
Doepfer_a100@yahoogroups.com
]
 > Gesendet: Dienstag, 22. November 2016 23:48
 > An:
Doepfer_a100@yahoogroups.com
 > Betreff: 1 A-198 Ribbon pressure offset (zero)
 >
 >
 > I am using the A-198 with a frac setup, originally powering from
 > a +/-12V supply but now trying to run it off of the +/-15V
 > supply. It does work fine with just one exception. The pressure
 > voltage now has a 3V offset. No finger on ribbon, panel pot fully
 > clockwise, I get 3V. More if I press. How can I adjust this Is
 > that what the trim pot is for
 >
 > Thank you
 >
 > Steve B