Hi Dieter thanks a lot for this specification
Otherwise, could I use the original 2.4A Doepfer transformer (which belongs to a case I already own) to operate the TWO kits simultaneously (Assuming that an adapter to double the plug could be found…)
Best, Diego
> Il giorno 03 lug 2017, alle ore 10:03,
yahoo@...
1 <
Doepfer_a100@yahoogroups.com
> ha scritto:
>
> You may use this power supply. But the max. output current is then only
> 500mA. Please refer to the information on our website:
>
> www.doepfer.com > English > PRODUCTS > A-100 > DIY case kit:
>
> "to operate the kit an external transformer with 14-16V/2.4A AC is required,
> the current of the transformer has to be twice the value of the +/-12V DC
> current, the max. value is 2.4A (corresponding to 1200mA for +/-12V DC),
> even smaller current output is possible; the current output of the power
> supply is half the current of the external transformer as the currents for
> both voltages +/-12V are required (if e.g. the transformer outputs max.
> 1000mA the max. power supply current is 500mA for +/-12V)"
>
> Best wishes
> Dieter Doepfer
>
>
>> -----Ursprüngliche Nachricht-----
>> Von:
Doepfer_a100@yahoogroups.com
[mailto:
Doepfer_a100@yahoogroups.com
]
>> Gesendet: Freitag, 23. Juni 2017 15:22
>> An:
Doepfer_a100@yahoogroups.com
>> Betreff: 1 Re: A-100 LC3 PSU ( )
>>
>>
>>
>>
>>
>> Sorry I was wrong in the description of the problem, forget it.
>>
>>
>> My worry here concerns the fact that a (not original) 1000mA
>> transformer is used for a (supposed) 1200mA power supply. I say
>> “supposed” because I don’t know whether this case came with a
>> lower supply mA value than today’s model (the original Doepfer
>> transformer installed today delivers 2400mA).
>>
>>
>> So, the PSU and the board are original Doepfer, the external
>> transformer is not.
>>
>>
>> Do you think this might cause issues to the power supply, the
>> board or the modules
>>
>>
>> The link describes the not original transformer..
>>
>>
>>
http://www.velleman.eu/products/view/ country=fr&lang=en&id=365838
>>
>>
>> Since I already own this case with 1200mA and the original ext.
>> transformer (2400mA), would be technically possible to use this
>> original transformer for both cases at the same time
>>
>>
>> Best,
>> dxx
>>
>>
>>
>>
>>
>>
>> Il giorno 18 giu 2017, alle ore 22:47, Diego Ragnini
>> <
diegora@...
> ha scritto:
>>
>>
>> Hi everybody
>>
>>
>> A guy sells a second hand 2,5 years old A-100 LC3 of 1000mA, with
>> a PSU which is not the original one. Apparently it had few issues
>> and decided to replace it for not clearly specified reasons. He
>> forwarded me the link for this PSU
>>
>>
>>
http://www.velleman.eu/products/view/ country=fr&lang=en&id=365838
>>
>>
>> I would be glad if someone could confirm the compatibility with
>> the Doepfer system. He states that everything works flawlessly
>> with it. I am surprised to know about issues on the original
>> transformer for this unit, which I own in the new version
>> (1200mA) and cannot find anything to complain about its PSU,
>> absolutely sturdy and reliable.
>>
>>
>> Best regards,
>> Diego
>>
>>
>>
>>
>>
>
>
>
> ------------------------------------
>
> ------------------------------------
>
>
> ------------------------------------
>
> Yahoo Groups Links
>
>
>