Hello,
please make sure that the output level of the Gate/Clock/Reset/Start/Stop
outputs is set to +12V (not +5V).
And make sure that the frequency of the A-147-2 is not too low. The
frequency of the A-147-2 should be not much less than the clock signal
coming from the Dark Time. Otherwise the period of the A-147-2 is to low to
generate a noticeable signal before the next reset appears.
Best wishes
Dieter Doepfer
> -----Ursprüngliche Nachricht-----
> Von:
Doepfer_a100@yahoogroups.com
[mailto:
Doepfer_a100@yahoogroups.com
]
> Gesendet: Dienstag, 25. Dezember 2018 19:52
> An:
Doepfer_a100@yahoogroups.com
> Betreff: 1 A147-2 VCDLFO question
>
>
> Hello and happy christmas to everyone,
>
> I am using an external clock e.g from dark time to sync/reset the A147-2,
> as soon as I am increasing the frequency knob of the lfo, the
> outputs are in perfect
> sync with the external clock. As soon as I am decreasing the
> frequency knob I have no
> output signal from the lfo, the leds are not blinking. Is it a
> normal behaviour
>
>
> Best regards,
> Miltos