Probably the range of the trimming potentiometer P18 (- adjust) was not
sufficient because P18 and R94 are connected in series. The effective value
of R94 (normally 22k) has been probably reduced by soldering a second
resistor in parallel to obtain the correct adjustment for P18. But I don't
think that the additional resistor is 10k because this would result in about
6,8k which is totally different from the 22k. I cannot imagine that the
value for R94 is that far away from the correct value for the P18
adjustment. I'd expect a higher value for the additional resistor (in the
47k...100k range).
I'd not recommend to remove the resistor as I think it has been added
intentionally.
Best wishes
Dieter Doepfer
> -----Ursprüngliche Nachricht-----
> Von:
Doepfer_a100@yahoogroups.com
[mailto:
Doepfer_a100@yahoogroups.com
]
> Gesendet: Montag, 25. Februar 2019 23:02
> An:
Doepfer_a100@yahoogroups.com
> Betreff: Re: AW: 1 Re: A-126 Malfunction
>
>
> But strange that one of my additional parts is a resistor, that
> has been soldered right at the same place of another resistor,
> but on the solder side.
> This resistor is R94/22K near the Up Output on the edge.
> The additional resistor is, I think, 10k; it is brown-black
> without a multiplier color.
>
> Should I remove it