--- In
Doepfer_a100@yahoogroups.com
, Bakis Sirros
<synth_freak_2000@y...> wrote:
> dieter says:>
> Christian is also about to put the finishing touches
> to the A-154 and he/we are not sure in some details.
> If it comes to the details it is not so easy to decide
> how the module should work. E.g. which pendulum type
> he should offer Should the first/last step played
> twice or only once (MAQ users will know the
> difference). In the first case the rhythmical
> structure remains the same by changing the running
> mode but the first resp. last step is played twice. In
> the second pendulum mode the first/last step is only
> played once.
I think it should both, perhaps you could use a switched pot at the
Mode Manual pot. Position in is played once, position pulled out is
played twice.
> And: should the CV addressed mode be triggered by the
> clock or be completely independent of the clock
I think both are very useful, a switched pot at the Clock Manual
position would take care of this.
We
> tend to the clock triggered version. To obtain a
> apparently clock independent operation one has simply
> to increase the clock tempo (e.g. 100Hz).
> Another "problem": What if first step CV is higher
> than last step CV Should the running mode be
> inverted (in case that backward mode is selected the
> sequence would run forward in this case) Or the step
> be fixed e.g. at the first step CV if first step CV is
> higher than last step CV
Again, same thing, both are useful. A switched pot.
regards,
rm