> > It's connected to the bus, so I can see the gate
> bus LED's lit when
> > there is midi data received, I have also tried
> patching it to any of my
> > A110 VCO's, still no use. It's odd, i know that
> the IC is working,
> > which would be the suspect thing if it were blown,
> as the gate outs are
> > okay.. so any ideas
>
> Explanation #1: There are 2 modules that "write" to
> the CV line of the bus.
> So far this could be the A-185 only (or two A-190).
> If you have an A-185 on
> the same bus the bus connections of the A-190 have
> to be interrupted as
> mentioned on page 4 in the A-185 manual.
>
> Explanation #2: The A-190 is defective or completely
> misadjusted. Try to
> measure the CV at the CV socket at the front panel.
> If there is no CV coming
> out reset the A-190 as described in the A-190
> manual. After that the CV
> scale and offset of the A-190 have to be re-adjusted
> (i.e. VCOs controlled
> by the A-190 will probably be detuned especially
> because of the unadjusted
> 1V/octave scale).
>
> Good luck
> Dieter Doepfer
>
>
=====