hello,
as far as i remember, (i haven't used my a156 for a
long time), the a156 does NOT pass the triggers that
it receives from it's trigger inputs to its trigger
outputs. the a156 output triggers ONLY when the
incoming cv changes.
so, if you send to the a156 a constant cv, it will
output NO triggers at all, no matter if you send
triggers to it's inputs.
send to the a156 a changing cv signal(for example from
an lfo) and you'll see that it generates triggers by
itself. if you send to the a156 a trigger signal to
it;s trigger inputs and a changing cv signal(for
example an lfo sine) to it's cv inputs, then the a156
will output triggers in sync to the input triggers,
only because at each input trigger that the a156
receives, it also receives a changing cv at the same
times.
the a156 trigger inputs are there only for "telling"
the a156 WHEN to quantize the incoming voltage.
so, depending in the incoming cv to be quantized,
sometimes the a156 will output triggers at the same
time as the triggers it receives in it's inputs and
sometimes not.
please, dieter, correct me if i'm wrong.
bakis.
--- phaeton777 <
phaeton777@...
> wrote:
>
> My A-156 quantizer has stopped passing the trigger
> pulse to the
> trigger out jacks. This is happening on both halves
> of the module.
> All other functions are working normally.
>
> Has anyone had this problem or does anyone know a
> repair
>
> Richard.
>
>
>
>
>
>
=====
Bakis Siros
Parallel Worlds / Polariton
Athens-Greece
1 group owner
http://www.shimarecords.co.uk
http://www.ward12.com
__________________________________
Do you Yahoo!
Meet the all-new My Yahoo! - Try it today!
http://my.yahoo.com