To answer my own question:
"Instead of voltage control even clock/reset controlled addressing of the
active step is possible. The rising edge of each clock signal causes an
advance to the next state. "
And:
"The digital output of the currently addressed turns to "high". All other
digital outputs are low. The digital outputs can be used to trigger e.g.
envelope generators or to control the reset input in the clocked mode to
reduce the number of addressed stages."
So hook it up with sequencer to the same clock, and you have independent
trigger on every step.
Regards,
Zoran
>From: "Zoran Bosnjak" <
dj_allin@...
>
>Reply-To:
Doepfer_a100@yahoogroups.com
>To:
Doepfer_a100@yahoogroups.com
>Subject: 1 Easy A-152 Question related to A-155 Sequencer
>Date: Tue, 02 Aug 2005 16:34:11 +0000
>
>Hello,
>
>can somebody confirm if I am right on this: A-152 Voltage Addressed
>Track&Hold / Switch can be used with A-155 to provide separate trigger out
>on every step (like Moog 960 sequencer, without trigger ins, of course). Is
>that correct Is there any other module that would do this (simple 8-way
>switch) Regards,
>
>Zoran
>
>