The single triggers are available at the 8 center terminals of the
trigger/gate switches (upper or lower row). You will simply have to add 8
sockets that are connected to the center terminals e.g. of the upper trigger
row (via 1k protection resistors to avoid problems with unintentional short
circuits). One could e.g. use a multiple module A-180 and interrupt the
connections between the sockets on the pcb and instead of this connect the 8
sockets to the switch terminals. Another solution would be to remove one row
of switches and replace the switches by single trigger sockets. But from my
point of view the trigger row witch switches is more flexible in most cases.
It's only a mechanical "problem" (where to place the sockets) to add single
trigger outputs, not an electronical one.
Best wishes
Dieter Doepfer
> -----Ursprüngliche Nachricht-----
> Von:
Doepfer_a100@yahoogroups.com
> [mailto:
Doepfer_a100@yahoogroups.com
]Im Auftrag von Zoran Bosnjak
> Gesendet: Dienstag, 2. August 2005 18:34
> An:
Doepfer_a100@yahoogroups.com
> Betreff: 1 Easy A-152 Question related to A-155 Sequencer
>
>
> Hello,
>
> can somebody confirm if I am right on this: A-152 Voltage Addressed
> Track&Hold / Switch can be used with A-155 to provide separate
> trigger out
> on every step (like Moog 960 sequencer, without trigger ins, of
> course). Is
> that correct Is there any other module that would do this (simple 8-way
> switch) Regards,
>
> Zoran
>
>
>
>
>
>
> Yahoo! Groups Links
>
>
>
>
>
>