Am 29.10.2012 01:53, schrieb ohmstudiste:
 > Hi,
 >
 > I got a mp4 that I recently recalibrated and is working very nicely. Tuning/scaling is very good.
 > I checked all the voltage and got good and steady readings on the power supply and keyboard CV voltages.
 >
 > But when it comes to measure the VCO offset in the klm398 I don't get the 0.000v +/- 1mv. Instead I read voltages bretween 1v and 3v and they change if I play notes on the keyboard. The voltages are responsive to the different VR on the board but I can't make them 0.000v.
 >
 > So question are:
 > - Am I reading the good points
i connected to J12 and to the respective 4 colour wires mentionned in the manual (and corrected here for new version)
 > - Is there a key to press while reading
 > - Is it dangerous for the OSC to have these readings
As i mentionned my mp4 is really nice tuned and scaled, for every oscillators.
Others may correct me, but I think you misunderstood the adjustment
 description: As far as I understand it right this is not a trimming to
 absolute 0.000V +/- 1mV, but the voltages should not vary more than 1mV
 in relation to each other.
 Florian
 --
http://fa.utfs.org/