Hello
The VCF adjustment always can be done by ear. I think you will only have
to adjust VR19 with the voltmeter, like described in the adjustment
instructions topic 6.1.
Then adjust VR18 like described in the adjustment instructions topic
6.2., but simply use your ear. Set the trimmer so that you just do not
hear the ringing of the highfrequency resonance. A slight change of the
cutoff down, should make the ringing appear immediately.
Florian
m 08.12.2015 um 05:37 schrieb
voltagegrove@...
[korg_mono-poly]:
>
>
> Just reviewed the calibration manual... I do not own an Oscilloscope.
> Is there any chance that I could manage without one
> By using my DVM and my ears
> Is there any chance that I could calibrate the filter with just my ears
>
> I know what a proper VCF should sound like. I own almost two dozen
> analog synths, both vintage and modern...
>
> Anything will help.
>
>
>