Now that I've got my 6R up and running, I would like to program my control freak for it so
that I can control it with knobs. It has a matrix 1000 setup already but that doesn't work
so far with the M6. Can somebody help me out with the sysex strings I need for parameter
changes. So far I've got the general:
F0H beginning of sysex
10H Oberehim code
06H For the M6R device ID
<opcode>
<data bytes>
F7H
But if somebody could fill me in with an example of say the VCF control string, I could
probably figure the rest out. I need to figure out what the opcodes and the data bytes are
for each parameter. I have found this text on the internet which I have been trying to
reference but can't quite figure it out without seeing a full string or a couple full strings.:
Statistics: 134 Bytes/Single Patch
= 268 nybbles transmitted + 5 bytes Header + 1 byte Checksum + 1
byte EOX
= 275 total transmitted bytes/Single Patch
Byte Parameter # Bits Description
0 - 7 6 each Patch Name
Each character is represented by the lower 6
bits of it's ASCII
representation.
8 48 2 Keyboard Mode
0 = Reassign
1 = Rotate
2 = Unison
3 = Reassign w/ Rob
9 00 6 DCO 1 Initial Frequency
LSB = 1 Semitone
10 05 6 DCO 1 Initial Waveshape
0 = Sawtooth
31 = Triangle
11 03 6 DCO 1 Initial Pulse Width
12 07 2 DCO 1 Fixed Modulations
Bit 0 = Lever 1
Bit 1 = Vibrato
13 06 2 DCO 1 Waveform Enable
Bit 0 = Pulse
Bit 1 = Wave
14 10 6 DCO 2 Initial Frequency
LSB = 1 Semitone
15 15 6 DCO 2 Initial Waveshape
0 = Sawtooth
31 = Triangle
16 13 6 DCO 2 Initial Pulse Width
17 17 2 DCO 2 Fixed Modulations
Bit 0 = Lever 1
Bit 1 = Vibrato
18 16 3 DCO 1 Waveform Enable
Bit 0 = Pulse
Bit 1 = Wave
Bit 2 = Noise
19 12 6 (signed) DCO 2
Detune
Byte Parameter # Bits Description
20 20 6 Mix
21 08 2 DCO 1 Fixed Modulations
Bit 0 = Portamento
Bit 1 = Not used
22 09 1 DCO 1 Click
23 18 2 DCO 2 Fixed Modulations
Bit 0 = Portamento
Bit 1 = Keyboard Tracking Enable
24 19 1 DCO 2 Click
25 02 2 DCO Sync Mode
26 21 7 VCF Initial Frequency
LSB = 1 Semitone
27 24 6 VCF Initial Resonance
28 25 2 VCF Fixed Modulations
Bit 0 = Lever 1
Bit 1 = Vibrato
29 26 2 VCF Keyboard Modulation
Bit 0 = Portamento
Bit 1 = Keyboard
30 30 6 VCF FM Initial Amount
31 27 6 VCA 1 (Exponential) Initial Amount
32 44 6 Portamento Initial Rate
33 46 2 Lag Mode
0 = Constant Speed
1 = Constant Time
2 = Exponential
3 = Exponential
34 47 1 Legato Portamento Enable
35 80 6 LFO 1 Initial Speed
36 86 2 LFO 1 Trigger
0 = No Trigger
1 = Single Trigger
2 = Multi Trigger
3 = External Trigger
37 87 1 LFO 1 Lag Enable
38 82 3 LFO 1 Waveshape (see Table 1)
39 83 5 LFO 1 Retrigger point
40 88 5 LFO 1 Sampled Source Number
41 84 6 LFO 1 Initial Amplitude
this is only a partial list,
anyways,
Thanks
Brian