Can you offer an explanation as to why I can get the bank change sysex
to work and not the parameter adjustment
For example, I am sending F0 10 06 06 54 00 F7 to try to get
Env. 1 release time to zero. I note that the manual says that the
values are "sign extended from 6 bit to 7 bit". Does that mean the
value byte is not literal
Thank you.
Peter
Quoting Margus Kliimask <
margus.kliimask@...
>:
> Wrong. This is a command from Matrix-6/6R sysex implementation, M-1000
> is different. On an M-1000 you need not do this, nor does this command
> get processed on M-1000. check out the page you referred.
>
> Regards,
> Margus
>
> On Wed, Aug 5, 2009 at 3:53 PM,
> bernard.escaillas<
bernard@...
> wrote:
>>
>>
>> You have to send a message once to enable 'remote sysex'.
>>
>> This message is F0 10 06 05 F7
>>
>> Note: the Matrix1000 has some bugs...
>> Read more here:
http://wolzow.mindworks.ee/analog/m1k-firmware.htm
>>
>> Be careful no to send sysex messages to fast or you will crash the Matrix...
>> Even if MIDI bauds are always the same, today midi port buffers are a lot
>> faster than in the 80's ;)
>>
>> Have fun
>>
>>
>
>
> ------------------------------------
>
> Yahoo! Groups Links
>
>
>
>