Hi
you are aware, that Env2 to Env 4 are NOT triggered by the trigger-in by
default but are connected to the comparator out
For testing set the "threshold" levels of Env1 to Env3 to at least 9
o'clock position. If you want to use them as normal envelopes you have
to connect the four Trigger Ins individually to the Gate from the
MIDI-Interface or Keyboard.
Florian
bellenger_a wrote:
> Hello,
>
> just got an A143-1 from MESI yesterday... trying it out this morning and from the MIX
> OUTPUT I can only get the ENV1... not the other ones... It seems this module is defective
> should I just bring it back or is there anything simple I could check before that
>
>
> Thanks, best/a
>
>
>
>
> Yahoo! Groups Links
>
>
>
--
Florian Anwander |ConSol
Tel. +49(89)45841-133 |Consulting&Solutions Software GmbH
Fax +49(89)45841-111 |Franziskanerstr. 38, D-81669 München
email:
florian.anwander@...
|
http://www.consol.de