Florian, thanks for this quick answer...
SO... I think (well I hope so!) that I understood pretty well the functionning of the module
as everything seems to be working for me BUT EXCEPT from the MIX OUTPUT...
OR MAYBE I AM ALL MIXING IT UP
BASICALLY:
from the MIX OUTPUT should I not be get (lets say with nothing patched in... all in LFO
mod, and with all Mix Polarizer knobs at +2) all ENVELOPS mixed together
My problem is that there is ONLY ENVELOP 1 which go to the MIX OUTPUT
/alexandre/
--- In
Doepfer_a100@yahoogroups.com
, Florian Anwander <Florian.Anwander@...>
wrote:
>
> Hi
>
> you are aware, that Env2 to Env 4 are NOT triggered by the trigger-in by
> default but are connected to the comparator out
> For testing set the "threshold" levels of Env1 to Env3 to at least 9
> o'clock position. If you want to use them as normal envelopes you have
> to connect the four Trigger Ins individually to the Gate from the
> MIDI-Interface or Keyboard.
>
> Florian
>
>
> bellenger_a wrote:
>
> > Hello,
> >
> > just got an A143-1 from MESI yesterday... trying it out this morning and from the MIX
> > OUTPUT I can only get the ENV1... not the other ones... It seems this module is
defective
> > should I just bring it back or is there anything simple I could check before that
> >
> >
> > Thanks, best/a
> >
> >
> >
> >
> > Yahoo! Groups Links
> >
> >
> >
>
> --
> Florian Anwander |ConSol
> Tel. +49(89)45841-133 |Consulting&Solutions Software GmbH
> Fax +49(89)45841-111 |Franziskanerstr. 38, D-81669 München
> email: florian.anwander@... |
http://www.consol.de
>