> Hello again!
 >
 > Sorry to bother you all again...but I have another question.
 > I have a A-112 sampler module and I want to trigger it from a
 > Doepfer pitch ribbon (the pitch ribbon has the external R2M box).
 > The strange thing is that I can't seem to trigger the A-112 from
 > the ribbon... I can trigger the A-112 from e.g. a LFO, and from
 > the A-155 sequencer. I am suspecting that the ribbon controller
 > is delivering to low voltage (or that the A-112 wants slightly
 > more "juice"). The strange thing is that the ribbon works fine
 > with other modules...
 > Anyone with similar experience..
 > Any good ideas... Any simple way to adjust the A-112
 >
 > Thanks,
 >
 > /Lars
This issue has been discussed already in April 2008 in this group (startin a
 message dated April 27, 2008).
 You probably own an A-112 manufactured before May 2008. In April 2008 it
 came up in this group that the R2M/A-112 combo has problems with the gate
 transmission because the A-112 gate input had a 10k load that reduces the
 gate voltage coming from the R2M to about 2V. And that's not sufficient to
 trigger the A-112. All A-112 manufactured from May 2008 are equipped with a
 100k resistor instead of 10k as we immediately changed the value of the
 corresponding resistor.
 If you are a bit familiar with electronics you may replace the 10k pull down
 resistor at the A-112 gate input to a higher value (e.g. 47k or 100k). It's
 the resistor R15 that is located just behind the Midi In socket (between
 Diode D5 and capacitor C21).
 Best wishes
 Dieter Doepfer