Hello
That is something which annoys me too.
I think the A160 should be dropped and a A160-2 should be introduced
instead which uses a CD4029, which can be switched between counting
up/down and also with a presettable reset position.
Florian
yahoo@...
schrieb:
>> Is it possible to modify the A-160 clock divider so that it
>> starts with firing all the gates and goes from there That it
>> counts from the top instead of from the bottom. Now I have to
>> wait say 32 clocks for it to fire the /32 gate for the first
>> time. It would be easier to run multiple clocked devices in sync
>> if they all started on the downbeat.
>>
>> Martin
>
> The A-160 uses a standard CMOS counter (CD4024) that cannot be modified.
> Maybe adding inverters do the job you are asking for . In this case all
> (inverted) outputs will turn high on each reset.
>
> Best wishes
> Dieter Doepfer
>
>
>
> ------------------------------------
>
> Yahoo! Groups Links
>
>
>
>