Hi Ricardo
> When I asked
> about the G6 connections he said: "ask Doepfer"
Ummmh. He is an experienced supporter ;-). I work in support for a large
businesse application, and sometimes it feels like the two words "ask
Microsoft" are the most said words in this job...
> Regarding the
> connection of the Mean Well input to the G6 Ac input , Where's the
> best place to do this , As you suggested , i shouldn't wire them to
> those connectors with blue caps (3rd picture) because they are
> connected with the fuses. So then , should i wire them together with
> the G6 black and blue AC input cables in their own connectors in the
> PSU board Does it matter which cable goes to each connector
Do not wire them to the Doepfer PSU at all. They should have there own
connection to the mains.
Either you add another power connector in the rear panel.
Or
* you add two fuse holders to the rear panel (like
http://www.conrad.de/ce/de/product/526245)
* connect the former black cable from the mains connector to these two
fuseholders.
* connect the other contact of one of the fuse holders to the black
connector of the Doepfer PSU and the other fuse holder to one of the
AC-In connectors of the Mean Well PSU.
* connect the former blue cable from the mains connector to the other AC
connector of both PSUs
* pick the fuse from the fuse holder in the mains socket and put it into
the new fuse holder for the Doepfer PSU
* place a 0.4A 250V fuse in the new fuse holder for the Mean Well PSU
* put a 6.3A 250V fuse in the original fuse holder in the mains socket.
Florian
--
http://fa.utfs.org/