Hi Danny
Am 17.07.2017 um 08:18 schrieb
syndromeda@...
[Doepfer_a100]:
> Anybody an idea what to do know
1.) Switch off the system
2.) remove the A-134-1 and disconnect it from the supply bus
3.) switch on the system and check whether the -12 volts are available again
* if yes -> the module needs repair
* if no
4.) switch off the system
5.) remove all modules from the rack, do not keep any module connected
to the power bus
6.) switch on the system and check whether the -12 volts are available
* if no -> shot on the supplybus or powersupply broken
* if yes
7.) switch off the system
8.) mount the first module
9.) switch on the system and check whether the -12 volts are available
* if yes -> do the loop from 7.) with the next module
* if no -> you have found the module which causes the -12 volts to
break down.
Florian
--
http://www.florian-anwander.de