Thanks for the hints. I do, in fact have four 8 channel sequencers. I
plugged various of the outputs to the reset socket on the A151. My
sequencers also have a selector knob (not standard) where I can
select the sequence length more quickly than patching a cable from an
output to the reset on them (They are An.Sol.SQ8's), and the only way
I could get the A151 to reset after 3 was to patch the cable from
channel 4 to the A151 reset socket, and at the same time have the SQ8
sequence length selector set to a length of 7. Now, if anyone can
figure out just why that works, they are better than I.
Richard
--- In
Doepfer_a100@yahoogroups.com
, "unknown freak"
<vogelscheiss@v...> wrote:
> I'll be interested to hear an answer to this one. I can't think
how this
> can be done without more modules -- you need something counting to
24. Of
> course the new A151 has a switch allowing you to use it as a 1:3.
With the
> old A151, in this configuration it seems like something that
requires
> another sequencer or sequential switch -- a trigger output on step
8 of
> sequencer 1 clocks the second sequencer, which resets after 3
steps, multing
> off the reset signal to the A151's reset input. I don't know,
maybe I'm
> full of sh_t on this. Other takers
>
> --Chuck
>
> -----Original Message-----
> From:
Doepfer_a100@yahoogroups.com
[mailto:
Doepfer_a100@yahoogroups.com
] On
> Behalf Of trebcavxx
> Sent: Friday, April 15, 2005 2:56 PM
> To:
Doepfer_a100@yahoogroups.com
> Subject: 1 Doepfer A151
>
>
>
> I've got a question about the Doepher A151 Sequential switch. Using
the
> switch in the fashion of inputting 3 CV feeds in, and taking an
output
> from the I/O socket, I'd need to input a reset signal into the
reset
> socket to cancel the 4th switching on each pass. Does anyone know
where
> I'd get the pulse from to do this
> I'm feeding in three CVs from three Analogue Sol sequencers into
1,2
> and 3, then taking the output from the I/O socket to my quantiser,
and
> then on to the CV input of a VCO. The switching pulse for the A151
is
> coming from the 1:8 output of my master clock. The 1:1 output goes
to
> the three sequencer's CLOCK inputs, (and also to the TRIG of an
> envelope generater), giving me the full 8 channels on a sequencer,
> which then switches to the next sequencer and so on, so we have in
> effect one 24 channel sequencer, but the resetting of the A151 is
> giving me a problem.
> Can anyone help please
>
>
>
>
>
>
>
>
>
> Yahoo! Groups Links