Hello Dieter and also to the rest of the folks on here. Thanks for
the feedback.
I checked page 10 in the manual, and since I am not sending midi
messages via an external controller, I think I might still be having
problems somewhere in the programming of the 190 itself. I have
tried every possible division (programming step at a time in the FLO
Freq/Clock menu) by hand, and everything still seems to send a non-
quartered (triplets ) hardware pulse to the filters that I am trying
to control. Would it be easier for me to just add a clock divider
module between the 190 and 155... and then send different divisions
to different dedicated filters and to the sequncer
Sixtoo
"You have to set the clock dividing factor to 6, 12 or 24 to get
1/16, 1/8 or
1/4 hardware clock pulses from the A-190. Please look at the A-190
manual to
page 10. I know that the A-190 operation is not the best (I would never
design the A-190 again as it is but it was develeoped by an employee in
cooperation with an external consultant - in the meantime I don't
think much
of external consultants but listen to the suggestions of this
group ....)"
Best wishes
Dieter Doepfer
[Non-text portions of this message have been removed]