Sixtoo,
the clock divider module A-160 will not really help as it divides only by 2,
4, 8 ...
I know that the A-190 programming is a bit awkward but it should be possible
to obtain the right dividing factor. Pay attention that in the A-190 manual
the program change numbers are counted from 1...128. Other manufacturers
count from 0...127. For some devices (especially software) you may be able
to select between the counting methods 0...127 and 1...128 (finally always
0...127 is sent by Midi but the display of the transmitting device may show
the range 0...127 or 1...128). Maybe you will have to subtract 1 from the
statements in the A-190 manual to obtain the right program change number.
You have to send e.g. Midi program change #3 (#2 if 0...127 is counted) or
#6 (#5 if 0...127 is counted) while you are in the CONFIG menu 2 (clock
time/polarity). Then you have to leave the CONFIG mode and look if the
dividing factor is correct. And you have to store the settings (page 17) to
have the same dividing factor available after power off/on.
Best wishes
Dieter Doepfer
> -----Ursprüngliche Nachricht-----
> Von:
Doepfer_a100@yahoogroups.com
> [mailto:
Doepfer_a100@yahoogroups.com
]Im Auftrag von Sixtoo.1200Hobos
> Gesendet: Dienstag, 7. Februar 2006 06:15
> An:
Doepfer_a100@yahoogroups.com
> Betreff: Re: 1 Digest Number 1401
>
>
> Hello Dieter and also to the rest of the folks on here. Thanks for
> the feedback. I checked page 10 in the manual, and since I am not sending
midi
> messages via an external controller, I think I might still be having
> problems somewhere in the programming of the 190 itself. I have
> tried every possible division (programming step at a time in the FLO
> Freq/Clock menu) by hand, and everything still seems to send a non-
> quartered (triplets ) hardware pulse to the filters that I am trying
> to control. Would it be easier for me to just add a clock divider
> module between the 190 and 155... and then send different divisions
> to different dedicated filters and to the sequncer
>
> Sixtoo
>
>
>
>
> "You have to set the clock dividing factor to 6, 12 or 24 to get
> 1/16, 1/8 or
> 1/4 hardware clock pulses from the A-190. Please look at the A-190
> manual to
> page 10. I know that the A-190 operation is not the best (I would never
> design the A-190 again as it is but it was develeoped by an employee in
> cooperation with an external consultant - in the meantime I don't
> think much
> of external consultants but listen to the suggestions of this
> group ....)"
>
> Best wishes
> Dieter Doepfer
>
>
>
> [Non-text portions of this message have been removed]
>
>
>
>
> Yahoo! Groups Links
>
>
>
>
>
>